Regardless of RCD type, e.g. AC, A, F or B, an alternating current test shall be used at the rated residual operating current (I Δn), with a maximum operating time not exceeding 300 ms for general non-delay type RCDs.

On-Site Guide (BS 7671:2018+A2:2022), 8th Edition - ISSWWW On-Site Guide (BS 7671:2018+A2:2022), 8th Edition - ISSWWW

All mechanical or electrical equipment has a finite lifespan. For RCDs, part of the product standard test procedure is to ensure a minimum number of operating cycles. BS EN 61008 requires RCDs having I Δn > 10 mA are subjected to 2000 operating cycles, each operating cycle consisting of a closing operation followed by an opening operation. This is a combination of manual operation, using the test button and using a test current of I Δn.RCD testers are designed and manufactured to BS EN 61557-6 Effectiveness of residual current devices (RCD) in TT, TN and IT systems for testing electrical installations. The standard requires that the instrument be able to verify correct disconnection of the supply in the event of a fault but it does not provide requirements for extensive product standard testing. Subsequently, not all instruments will be well suited to carrying out anything more than the most rudimentary of tests. What are the different characteristics of the Type A setting on the test instrument?

On-Site Guide (BS 7671:2018+A2:2022), 8th Edition

It was noted that those testing RCDs in the field would find it difficult to carry out the variety of tests permitted and may not know which of the available tests would be applicable to a given make or type of RCD. If the Type A RCD setting is selected on the test instrument, the test current is increased by a factor of 1.4. Therefore, if the instrument is set to perform a test on a 30 mA RCD at five times I Δn, a test current of 210 mA (30 x 5 x 1.4 = 210 mA) would be produced which may not be sufficient to operate the RCD within the required time as the product standard requires a test current of 350 mA (0.35 A), as described previously. It is essential to understand the limitations of the test instrument and product standard requirements when testing RCDs using the available RCD Type settings on the test instrument. Mark Coles, Head of Technical Regulations at the IET, said: “The IET is the authority for electrical installations in the UK and ensures that the National Wiring Regulations Committee carefully considers all necessary updates to the Regulations to ensure they best meet the needs of the industry. Regulation 422.1 (Precautions where particular risks of fire exist. General) now introduces requirements for the fire safety design of the building(s) to be documented. Regulation 422.2 (Conditions for evacuation in an emergency) introduces separate requirements for escape routes and a new concept of ‘protected escape routes’. Reference to conditions BD2, BD3, and BD4 have been deleted. Chapter 44 Protection against voltage disturbances and electromagnetic disturbancesPost-Brexit, this Amendment sees the further adoption of CENELEC Harmonized Documents as the UK continues the inclusion of standards for new and developing technologies. Individual PEIs are considered to be an electrical installation (for example, a private house or workshop) that can either produce or consume electrical energy. Three operating modes are considered for individual PEIs. These are:

Gold package - Institution of Engineering and Technology

BS 7671:2018+A2:2022 includes several new updates that are considered essential for anyone engaged in electrical installation activities. It provides information and guidance relating to the design, construction, inspection, testing and certification of domestic electrical installation work, and is intended to promote good practice and aid understanding of the fundamental concepts of protection for safety.There is a wide range of microgeneration technologies, including solar PV, wind turbines, small-scale hydro, and micro combined heat and power (CHP). BS 7671:2018+A2:2022 Requirements for Electrical Installations, IET Wiring Regulations, 18 th Edition. These changes reflect requirements in European and international standards, as well as input from the Health & Safety Executive (HSE) and the Independent Review of Building Regulations and Fire Safety (2018). There is no longer a requirement to perform a test using a test current equal to or higher than five times the rated residual current. What is an alternating current test?

BS 7671:2018+A2:2022 Changes to RCD testing in BS 7671:2018+A2:2022

BS EN 61008-1:2012+A12:2017 Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs). General rules. For further information on the different RCD Types and the selection process, see IET Wiring Matters article (Issue 77 September 2019), ‘Which RCD Type?’

How updates are published

Collective PEIs are considered to be several consuming electrical installations connected to the same public distribution network and sharing one common set of local power supplies and energy storage equipment. A PEI is considered to be a low-voltage electrical installation connected (or not) to a public distribution network (the grid), able to operate with local power supplies (for example, PV panels or wind turbines), and/or with local storage units (for example, batteries). It monitors and controls the energy from the connected sources delivering it to current-using equipment (for example, motors, heating, lighting, and appliances such as washing machines, etc), and/or local storage units (for example, batteries), and/or the public distribution network. When the Type A setting is selected on the instrument, a half wave pulsating residual test current superimposed on a smooth direct current of 6 mA is produced, which effectively applies a 1.4 multiplier to the rated residual current (I Δn). For example, if the 30 mA setting is selected, the RCD will be subjected to a test current of 42 mA (30 x 1.4 = 42 mA). Regulation 443.4.2 requires protection against overvoltages to be considered in the case of equipment likely to produce switching overvoltages or disturbances and gives conditions.